To improve site security, install lighting near entrances, equipment and machinery, and other valuable or dangerous areas. The outstations are required to be located on escape routes and fire exits, with additional outstations in higher risk areas such as plant rooms, commercial kitchens and laundries. It is a simple procedure but necessary to check it is operating properly for optimum fire safety. In premises in which the location of the master station is such that the audible fault warning signal could go unnoticed for longer than 24 hours, a special check should be carried out each day to confirm that either the equipment indicates normal operation, or that any fault indication is receiving necessary attention. It is important to note that if the fire alarm is linked to an alarm receiving centre (ARC) that the ARC is contacted immediately before and immediately after the weekly fire test, to ensure unwanted alarms are avoided and that the fire alarm signals are received appropriately. In the old days, fire alarms were very low-tech. Fire alarms and smoke detectors are usually things that we take for granted. Both types operate on the same principle, as heat or smoke detectors that are triggered manually or automatically.

In larger premises, it may be more appropriate to test two or three outstations each week, to ensure all devices are tested over the same length of time. To keep your construction site more secure. To find out more about how 1st Class Protection can help tighten your industrial and construction site security, why not give us a call today. Although the requirement for this work is to be done annually, the works detailed may be carried out over the course of two or more service visits during a 12 month period. In smaller premises, it is acceptable to test just one location each week – so for example within a premises where there are a small number of outstations, these could all be tested over a two month period in rotational order. Ideally, this would be recorded in a fire logbook every week and retained for any future inspection by the local fire and rescue service or any other recognised third party.

It is important to know where the alarm panel is located and to familiarise yourself with it, so you know it is working properly to ensure detection in the event of a fire. The impact of COVID-19 has added an extra layer to your list of challenges, forcing us all to approach our working practices in a different way. It would additionally be necessary to identify any changes in use, layout and construction of the building that may impact on the effectiveness of the system. How should the testing of the fire alarm system be carried out? There are two types of fire alarm systems, manual and automatic. It would also be necessary for the competent person to identify any deficiencies, such as an inadequate amount of fire alarm manual call points, low audibility of fire alarms in areas and a lack of detection relating to the category of fire alarm installed, as well as any wiring or signal faults identified. Who should test the fire alarm system? During the 2012 Olympics Fire Systems Ltd, designed and installed a wireless fire alarm system for a camp site with temporary accommodation for the cleaning staff for the Olympic stadium. Removed when necessary which makes them ideal as a temporary solution.

Not all wireless fire alarm systems need to be specified in an emergency, in fact a temporary wireless fire alarm system can, and should be, factored into the planning for use during periods of building and construction works. So in most cases where householders use CCTV, they should disable audio recording. Yes, the requirements for smoke alarms and fire doors are often separate, although there could be overlapping requirements that reduce the need for one if you have more of the other, in specific cases. An automatic fire alarm detects fire by monitoring environmental changes such as heat, https://www.keysure.co.uk smoke and carbon dioxide (depending on the type of fire). Any recorded false alarms or faults in the fire logbook should also be investigated and where possible, rectified to completion. In accordance to BS 5839-1: 2019, it is essential that the fire alarm system is subject to periodic inspection and servicing, so that any unrevealed faults are identified and addressed to restore the integrity of the system. How should the fire alarm testing be recorded? BS 5839-6: 2019 section 25.1 states that the testing of a fire alarm does not require any specialist knowledge, and can normally be carried out quite easily.